1.0 Product Information
Vitorond 100 is a floor-standing, oil-fired boiler of cast iron sectional design, with a genuine triple-pass heat exchanger.
There are multiple burner and control options available for this boiler.
Standard Equipment:
Boiler shell with insulation, stainless steel combustion chamber insert, installation fittings c/w 30 psig pressure relief valve,
drain valve, and Tridicator.
Standard Warranty:
In residential applications, limited 20 year warranty for cast iron sections, and 2 year warranty for boiler enclosure,
combustion chamber, burner, controls and accessories. In commercial applications, limited 10 year warranty for cast iron sections,
and 2 year warranty for boiler enclosure, combustion chamber, burner, controls and accessories. See
warranty sheet for details.
Certifications and Listings:
CSA, CRN, ASME, NY City approval, AHRI, CEC, Energy Star
1.1 Technical Data for VR1-33
CSA input *1 |
140 1.0 |
MBH GPH |
41 3.79 |
kW L/hr |
CSA output |
122 |
MBH |
36 |
kW |
Net AHRI rating |
106 |
MBH |
31 |
kW |
A.F.U.E. |
87 |
% |
|
|
Boiler dimensions |
Depth (without burner) |
31 |
inches |
790 |
mm |
Width |
15½ |
inches |
391 |
mm |
Height |
30½ |
inches |
775 |
mm |
Overall dimensions with jacket |
Total depth, including burner |
44 |
inches |
1116 |
mm |
Total width |
19¾ |
inches |
500 |
mm |
Total height, without Vitotronic |
33 |
inches |
840 |
mm |
Total height, with Vitotronic control |
– Height 1 (control in position for operation / programming) |
43⅞ |
inches |
1115 |
mm |
– Height 2 (control in position for servicing) |
52¾ |
inches |
1340 |
mm |
Height of boiler stand |
9¾ |
inches |
250 |
mm |
|
Weight of boiler block |
337 |
lbs |
153 |
kg |
Total weight of boiler with insulation, burner & control |
447 |
lbs |
203 |
kg |
|
Boiler water content |
11.6 |
USG |
44 |
L |
Max. operating pressure *2 |
30 |
psig |
207 |
kPa |
Boiler water connections |
Supply and return |
1½ |
inches |
|
|
Safety supply |
1½ |
inches |
|
|
Drain valve |
1½ |
inches |
|
|
Boiler vent connection *3 |
Outer diameter |
5 |
inches |
|
|
Gross flue gas temperature *4 |
– at boiler water temperature of 104°F / 40°C |
311 |
°F |
155 |
°C |
– at boiler water temperature of 167°F / 75°C |
356 |
°F |
180 |
°C |
|
Required flue draft |
-0.02 |
"w.c. |
|
|
Notes:
*1 |
Combustion results are based on 11.0% to 13.5% CO2 with fuel oil #2 and a hot water heating system supply temperature of 167°F / 75°C, return 140°F / 60°C. |
*2 |
Max. operating pressure is 45 psig / 310 kPa in all Canadian provinces where a CRN is not required, and in the U.S.A. |
*3 |
A 5" vent pipe adaptor is shipped with VR1 models 22 to 33 and 91 to 140. The vent pipe adaptor is not supplied with boiler models 40 to 63 and 161 to 245. |
*4 |
Measured flue gas temperature with combustion air temperature of 68°F / 20°C. |
1.2 Dimensional Drawings
Vitorond 100 with Aquastat/Hydrostat – Front and Side Views |
|
Legend
Dimensions
|
Vitorond 100 with Aquastat/Hydrostat – Rear View |
|
Legend
BD |
Boiler drain |
BHL |
Boiler high limit |
BWR |
Boiler water return |
BWS |
Boiler water supply |
FGC |
Flue gas collar |
SR |
Safety return |
SS |
Safety supply |
Dimensions
d |
5½" |
137 mm |
e |
23" |
585 mm |
f |
26¼" |
667 mm |
g |
28½" |
726 mm |
h |
33" |
840 mm |
|
1.3 Minimum Clearances
Clearances to Combustibles |
Top |
6" / 150 mm |
Sides |
0" / 0 mm |
Flue |
9" / 230 mm |
Rear |
6" / 150 mm |
Floor |
Combustible |
Recommended Minimum Service Clearances |
|
1.4 Waterside Flow
Pressure Drop and Flow Rates |
|
Legend
(A) VR1-33
|
Burner Data
|
Beckett Oil Burner
NX Series
Single-stage, forced-draft oil burner for chimney and direct vent applications.
|
1.0 Technical Data for Beckett NX
Beckett model |
NX-VI 503 |
|
|
|
Fuel type |
No. 2 |
fuel oil |
|
|
Input |
140 |
MBH |
41 |
kW |
Oil nozzle flow rate |
1.00 |
USG/hr |
3.79 |
ltr/hr |
Oil nozzle |
Delavan |
0.75x60°A/W |
|
|
|
|
Pump pressure |
175 |
psig |
1207 |
kPa |
Air tube length |
7 |
inches |
178 |
mm |
Air tube insertion |
3⅝ |
inches |
92 |
mm |
Electrical rating |
Voltage |
120 |
Volts |
|
|
Frequency |
60 |
Hz |
|
|
Phase |
Single |
phase |
|
|
Operating load (max.) |
5.8 |
Amps |
|
|
Dimensions (with cover) |
Depth |
9¼ |
inches |
235 |
mm |
Width (max.) |
15 |
inches |
381 |
mm |
Height (max.) |
12½ |
inches |
318 |
mm |
Air tube diameter |
3¼ |
inches |
83 |
mm |
Technical information subject to change without notice.
Viessmann reserves the right to correct errors in graphics, files, text and technical data.
Some product may not be exactly as illustrated.
Viessmann will not be held liable, financially or otherwise, for product changes, discontinuations or delays.
© Viessmann Manufacturing Company Inc. All rights reserved.
Viessmann is a trademark of Viessmann Group GmbH & Co. KG, and is registered with the U.S. Patent and Trademark Office.
For further copyright, trademark and disclaimer information, please visit:
www.viessmann.ca/en/copyright.html